Schneider BMXDDM16025H Hybrid discrete input/output module, 8-point input 24VDC, sink type, IEC3 category; 8-point output DC/AC relay output, 24VDC, 24-240VAC, 3A; 20-point terminal block
main information
Product Series
Modicon X80
product type
Digital I/O module
Application field
Used in harsh environments
Discrete input quantity
8
Input type
Sink type (positive logic)
Discrete input voltage
24 V DC, discrete input logic: positive
Discrete input current
3.5 mA
Discrete output quantity
8
Solid state output type
Relay
Discrete output voltage
24 V 19...30 V DC
24...240 V 19...264 V AC
Discrete output current
2000 mA
Additional information
Input compatible
With 2-wire/3-wire proximity sensor conforming to IEC 60947-5-2
With 2-wire/3-wire proximity sensors conforming to IEC 61131-2 type 3
Sensor power supply
19-30 V at <60 °C
21.1...29.0 V at <70 °C
Current status guarantee 1
>= 2 mA
Current state guarantee 0
<= 1.5 mA
input resistance
6800 Ω
Insulation resistance
> 10 MΩ 500 V DC
Power consumption W
3.1 W
DC typical response time
4 ms
DC maximum response time
7 ms
Output response time
<= 8 ms off
<= 10 ms activation
Parallel input
no
Typical power consumption
79 mA at 3.3 V DC
MTBF reliability
835303 H
Type of protection
1 external fuse per input channel 0.5 A fast blow
Input reverse polarity protection
1 external fuse per output channel or group of output channels
Voltage monitoring threshold
<14 V DC sensor fault
> 18 V DC transformer OK
Minimum switching current [Imin]
1 mA 5 V DC
Maximum switching voltage
125 V DC
264 V AC
Mechanical life
20000000 times
Electrical life
AC-14: 100000 cycles on 120 VA 240 V on 70 °C (load factor 0.7)
AC-14: 100000 cycles at 150 VA 200 V at 70 °C (load factor 0.7)
AC-14: 100000 cycles on 240 VA 240 V on -25…60 °C (load factor 0.7)
AC-14: 100000 cycles on 300 VA 200 V on -25…60 °C (load factor 0.7)
AC-15: 100000 cycles at 100 VA 200 V at 70 °C (load factor 0.35)
AC-15: 100000 cycles on 120 VA 240 V on -25…60 °C (load factor 0.35)
AC-15: 100000 cycles on 200 VA 200 V on -25…60 °C (load factor 0.35)
AC-15: 100000 cycles on 60 VA 240 V on 70 °C (load factor 0.35)
DC-13: 100000 cycles at 12 W 24 V at 70 °C
DC-13: 100000 cycles on 24 W 24 V on -25…60 °C
AC-14: 300000 cycles on 36 VA 240 V on 70 °C (load factor 0.7)
AC-14: 300,000 cycles at 40 VA 200 V at 70 °C (load factor 0.7)
AC-14: 300000 cycles on 72 VA 240 V on -25…60 °C (load factor 0.7)
AC-14: 300000 times on 80 VA 200 V on -25…60 °C (load factor 0.7)
AC-15: 300,000 cycles at 18 VA 240 V at 70 °C (load factor 0.35)
AC-15: 300,000 cycles on 30 VA 200 V on 70 °C (load factor 0.35)
AC-15: 300,000 cycles on 36 VA 240 V on -25…60 °C (load factor 0.35)
AC-15: 300,000 cycles on 60 VA 200 V on -25…60 °C (load factor 0.35)
DC-13: 300000 cycles on 3.6 W 24 V on 70 °C
DC-13: 300000 times on 7.2 W 24 V on -25…60 °C
On-off level
1 Hz
LED status
1 LED (green)module operating (RUN)
Channel diagnosis: 1 LED (green) per channel
1 LED (red)module error (ERR)
1 LED (red)module I/O
Product Weight
0.135 kg
surroundings
IP protection level
IP20
Comply with the directive
2014/35/EU-low voltage directive
2014/30/EU-electromagnetic compatibility
Environmental characteristics
Gas resistant class Gx
Gas resistant class 3C4
Dust resistant class 3S4
Sand resistant class 3S4
Salt resistant level 2
Mold growth resistant class 3B2
Fungal spore resistant class 3B2
Insulation performance
1500 V AC at 50/60 Hz 1 minute, primary/secondary
2830 V AC at 50/60 Hz for 1 minute, output relay
500 V DC for 1 minute, between I/O groups
Anti-vibration
3 gn
Impact resistance
30 gn
Storage temperature
-40…85 °C
Operating temperature
-25…70 °C
Relative humidity
5…95% at 55 °C without condensation
Protection treatment
Three anti-coating
Working altitude
0...2000 m
2000...5000 m Yes
Contact: Mr.wu
Phone: 0086+13808548642
Tel: 0086+13808548642
Add: 99 Luojiang District, Quanzhou, Fujian
Email: 190807896@qq.com