Schneider 140AII33000 Built-in safe temperature input module-Modicon Quantum-8 I
main information
Product Series
Modicon Quantum automation platform
product type
Intrinsically safe temperature input module
Software authorization
Concept V2.2 and above
Unity Pro
Filter type
Insert notch input filter 50/60 Hz thermocouple
Single low-pass input filter 20 Hz thermocouple
Additional information
Product Features
Use with product for area 20, 21 or 22
Number of analog inputs
8
Analog input type
Low voltage level: -100...100 mV
Low voltage level: -25...25 mV
Thermocouple:-210...760 °C for thermocouple J
Thermocouple:-270...1000 °C for thermocouple E
Thermocouple:-270...1370 °C for thermocouple K
Thermocouple:-270...400 °C for thermocouple T
Thermocouple:-50...1665 °C for thermocouple R
Thermocouple:-50...1665 °C for thermocouple S
Temperature probe:-200...850 °C for Pt 100, Pt 200, Pt 500, Pt 1000
Temperature probe:-60...180 °C for Ni 100, Ni 200, Ni 500, Ni 1000
Thermocouple:-130...1820 ° C for thermocouple B
Measuring current
0.5 mA Pt 500, Pt 1000, Ni 500, Ni 1000
2.5 mA Pt 100, Pt 200, Ni 100, Ni 200
Power supply resistance
<200 Ohm thermocouple
input resistance
> 10 MΩ RTD
> 1 MOhm thermocouple
common mode rejection
> 100 dB 50/60 Hz RTD
> 120 dB 50/60 Hz thermocouple
Node cold compensation
Internal 0…60 °C thermocouple
Linearity
0.003% RTD of full scale
Resolution
0.76 µV (16 bits) -25...25 mV millivolt
3.05 µV (16 bits) -100...100 mV millivolt
1 °C, 0.1 °C, 1 °F, 0.1 °F thermocouple
12 bits + mark (0.1 °C) RTD
measurement accuracy
+/- 2 °C + 0.1% of reading Thermocouple E
+/- 2 °C + 0.1% of reading Thermocouple J
+/- 2 °C + 0.1% of reading Thermocouple K
+/- 2 °C + 0.1% of reading Thermocouple T
+/- 4 °C + 0.1% of reading Thermocouple B
+/- 4 °C + 0.1% of reading Thermocouple R
+/- 4 °C + 0.1% of reading Thermocouple S
+/- 0.5 °C RTD at 25 °C
+/- 0.9 °C RTD on 0…60 °C
20 µV + 0.1% of reading millivolt at 25 °C
Absolute accuracy error
+/- 0.05% of full scale RTD at 25 °C
+/- 0.1% of maximum full scale RTD at 25 °C
Temperature deviation accuracy
0.15 mV/°C + 0.0015% of reading/°C maximum thermocouple
Update time
1 s TC/millivolt thermocouple
1.35 s 3-wire RTD
750 ms 2 or 4 wire RTD
Insulation between each channel and bus
1780 V 47...63 Hz AC for 1 minute
2500 V DC for 1 minute
Fault type
Disconnected
Over range
Power consumption W
2 W
Hot swap replacement spare
Not allowed by its own safety standards
Protection type
Internal fuse
Logo
CE
II1 G/D-EEx ia IIC
Demand bus current
400 mA
Module classification
standard
Product Weight
0.3 kg
surroundings
Standards compliant
EN 50281-1-1
EN 50014
EN 50284
CSA C22.2 No 142
EN 50020
Directive ATEX 94/9/EC
EN 50039
Dust zone
Outer area
certified product
Hazardous location category 1, category 1, group A, B, C
C-Tick.1
FM, Category 1, Category 2
SIRA 02ATEX2345X
Anti-static discharge
4 kV contacts conforming to IEC 801-2
8 kV broadcast conforming to IEC 801-2
Anti-electromagnetic domain
10 V/m 80…2000 Hz conforming to IEC 801-3
Operating temperature
0…60 °C
Storage temperature
-40…85 °C
Relative humidity
95% non-condensing
Working altitude
<= 5000 m
Contact: Mr.wu
Phone: 0086+13808548642
Tel: 0086+13808548642
Add: 99 Luojiang District, Quanzhou, Fujian
Email: 190807896@qq.com
Notes: All products enjoy a 6-month warranty